 +==== Debug ====
 +  * If you receive dumb values from a sensor, usually mean the bugOne can find this sensor. This can be a wiring error, or a wrong power mode (check parasite mode).
 +  * If you receive 850 (85.0°), usually mean the bugOne found the sensor but was unable to read the value. This usually occurs with bad connexion, for example on a breadboard. I spent some time on this error, but it's always a hardware failure not a software bug. 